If Radon Pipe Does Not Extend Above Roof Line
Install the vertical pipe.
If radon pipe does not extend above roof line. In a house with forced air heating and cooling radon gas can easily be distributed throughout the entire dwelling. Item 14 2 8 to prevent re entrainment of radon the point of discharge from vents of fan powered soil depressurization and block wall depressurization systems shall meet all of the following requirements. Utilize a varmint guard to keep debris out of the fan. Ensure that the slab and or vapor barrier do not cover the vertical opening of the t connector but are sealed around it.
It happens all the time. Often the interior pipe is extended through the attic roof without an exhaust fan. Run the pipe up through the interior of the house and through the roof. So to recap the pipe must terminate 12 above a roof.
Supports for radon vent pipes shall be installed at least every 6 feet on horizontal runs. Radon gas is approximately 7 5 times heavier than air. Install the concrete slab or polyethylene vapor barrier or both over the ground. 1 be above the eave of the roof 2 be ten feet or more above the ground level 3 be ten feet or more.
Why must radon be vented into the air above my home s roof. Another important aspect of the radon piping installation is that it must vent 12 above a roof of the building not highest roof or above the peak is required. In this example even though it does not technically adhere to the epa radon mitigation standards it does adhere to the heart of the safety issue. The critter and the fan rarely survives.
If tests show radon has decreased then we never install the exhaust fan. However the interior solid pipe not perforated needs to be extended through the attic and connected to an exhaust fan. The vent exhaust needs to be 12 inches above any roof area. The pipe must vent above the roof and be at least 10 from the ground the vent pipe must be 10 from windows unless 2 inches above a window.
Also the pipe must be at least 10 feet from any windows or skylights that can be opened this can be disregarded if the pipe is 2 above the opening. Install an in line fan. The system vents through the basement and then upwards in a pvc pipe on the side of the house. If running the pipe along side a window the exhaust point must be 2 above it and 12 above the eve too.
Even though the radon pipe does not extend above the roof as close to the ridge as possible it discharges the radon gas in a safe way while reducing the vent height by 15 to 20 feet. Vertical runs shall be secured either above or below the points of penetration through floors ceilings and roofs or at least every 8 feet on runs that do not penetrate floors ceilings or roofs.