Ibc Chapter 15 Roof Slope
For roof slopes from two units vertical in 12 units horizontal 17 percent slope up to four units vertical in 12 units horizontal 33 percent slope double underlayment application is required in accordance with section 1507 2 8.
Ibc chapter 15 roof slope. However many other parts of the code deal with aspects of roofing. Chapter 15 roof assemblies and rooftop structures section 1501 general 1501 1 scope. For roof slopes from two units vertical in 12 units horizontal 17 percent slope up to four units vertical in 12 units horizontal 33 percent slope double underlayment application is required in accordance with section 1507 2 8. Roof coverings installed on low slope roofs roof slope 2 12 in accordance with section 1507 shall resist impact damage based on the results of tests conducted in accordance with astm d3746 astm d4272 cgsb 37 gp 52m or the resistance to foot traffic test in section 5 5 of fm 4470.
Minimum roof slope roof pitch r905 15 1 liquid applied roofing must have a design roof slope of 1 4 12 or greater 2 slope. One fastener per tile. The primary roofing chapter in the ibc is chapter 15 roof assemblies and rooftop structures. The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Cold climates create unique conditions for roof design and prevention of ice and snow related damages. The primary roofing chapter in the irc is chapter 9 roof assemblies. Roof slope 3 12 and over. The provisions of this chapter shall govern the design materials construction and quality of roof assemblies and rooftop structures.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures. 1507 2 3 underlayment underlayment shall comply with section 1507 1 1. Having a width no greater than 16 inches. All structural metal roofing systems having a thickness equal to or greater than 22 gage and all nonstructural metal roof systems having a thickness equal to or greater than 26 gage shall be exempt from the.
For roof slopes from two units vertical in 12 units horizontal 17 percent slope up to four units vertical in 12 units horizontal 33 percent slope double underlayment application is required in accordance with section 1507 2 8. Proper ventilation is also important for performance in cold climates and the ability to shed or retain snow must also be considered. Only one fastener on slopes of 7 12 and less for tiles with installed weight exceeding 7 5 lbs sq. Roof slope up to 3 12.
This means for every 12 horizontal units the roof must rise a minimum of one fourth vertical unit. Flat tile without vertical laps two fasteners per tile.